Author Search Result

[Author] Toshio NOJIMA(31hit)

21-31hit(31hit)

  • Noise Reduction Device Using Novel Automatic Wavelength-Offset Control for Highly Stable Optical-Microwave Transmission Systems

    Toshiyuki FUTAKATA  Yoshiaki TARUSAWA  Yasushi ITO  Toshio NOJIMA  

     
    PAPER-Active Devices

      Vol:
    E79-C No:5
      Page(s):
    657-663

    A multi-terminal serial optical link(MSOL) achieves very simple and cost effective radio cell configurations because only one pair of fibers is needed. In addition, low cost Fabry-Perot laser diodes(FP-LDs) can be employed. MSOL has a substantial problem in that the beat noise degrades the C/N in the up-link. To reduce this noise, we propose using an automatic wavelength-offset control(AWOC) circuit. The AWOC circuit offsets the LD wavelength by controlling the laser bias current to minimise the RF band beat noise which is inherent in MSOL systems, and enables high C/N optical-microwave transmission. An experimental MSOL consisting of 5 radio access stations, each equipped with AWOC, is constructed to estimate the noise free dynamic range for 800-MHz 20-carrier signal transmission. The up-link comprises a single mode fiber connecting five 1.3-µm FP-LDs operating at 0.2 mW. The down-link consists of a single mode fiber and one 1.3-µm Distributed Feedback type Laser Diode(DFB-LD) emitting at 4.0 mW. The experimental device achieves over 15 dB noise reduction compared to MSOL without AWOC in the temperature range of 0 to 40. By using the proposed AWOC, MSOL can achive low cost optical fiber RF microcell systems that are easy to install. Additionally, when we install MSOL in the radio base station, the links become more cost effective than coaxial cable links; they offer a wide dynamic range and higher transmission quality.

  • FDTD Analysis of Electromagnetic Interaction between Portable Telephone and Human Head

    Masao TAKI  So-ichi WATANABE  Toshio NOJIMA  

     
    INVITED PAPER

      Vol:
    E79-C No:10
      Page(s):
    1300-1307

    Finite-difference time-domain (FDTD) analysis is performed to evaluate the distributions of specific absorption rate (SAR) in a human head during use of a handheld portable telephone. A heterogeneous head model has been assumed which is comprised of 273 108 cubic cells 2.5 mm on a side, with the electrical properties of anatomical equivalents. A handset model has been assumed to be a metal box with either a quarter-wavelength monopole or a half-wavelength dipole operating at 900 MHz or 1.5 GHz. The maximum local SARs in the head are evaluated under various exposure conditions. The dependence of the maximum local SARs on the difference in the structures or parameters of the model, i.e. the distance between the antenna and the head, the heterogeneity of the head, the antenna type, the volume of the smoothing region of the local SAR value, skin electrical constants, and the presence or absence of auricles, are examined. It is shown that the heterogeneity of the head barely affect the maximum local SAR when the telephone is located sufficiently close to the head. It is also shown that the electrical constants of skin which has lower conductivity provide the lower maximum local SAR in the head while the maximum local SAR within the brain is not significantly affected. The auricle which lies in closest proximity to the antenna is shown to have significant effect on the maximum local SAR. It is suggested that the presence of the auricle enhances the maximum local SAR by a factor that is 1.7-2.4 larger than the model without auricles.

  • Experimental Quasi-Microwave Whole-Body Averaged SAR Estimation Method Using Cylindrical-External Field Scanning

    Yoshifumi KAWAMURA  Takashi HIKAGE  Toshio NOJIMA  

     
    PAPER-Biological Effects and Safety

      Vol:
    E93-B No:7
      Page(s):
    1826-1833

    The aim of this study is to develop a new whole-body averaged specific absorption rate (SAR) estimation method based on the external-cylindrical field scanning technique. This technique is adopted with the goal of simplifying the dosimetry estimation of human phantoms that have different postures or sizes. An experimental scaled model system is constructed. In order to examine the validity of the proposed method for realistic human models, we discuss the pros and cons of measurements and numerical analyses based on the finite-difference time-domain (FDTD) method. We consider the anatomical European human phantoms and plane-wave in the 2 GHz mobile phone frequency band. The measured whole-body averaged SAR results obtained by the proposed method are compared with the results of the FDTD analyses.

  • 2-GHz Band Cryogenic Receiver Front End for Mobile Communication Base Station Systems

    Toshio NOJIMA  Shoichi NARAHASHI  Tetsuya MIMURA  Kei SATOH  Yasunori SUZUKI  

     
    PAPER

      Vol:
    E83-B No:8
      Page(s):
    1834-1843

    An ultra low-noise and highly selective, experimental 2-GHz band cryogenic receiver front end (CRFE) has been newly developed for cellular base stations. It utilizes a high-Q superconducting filter, a very low noise cryogenic amplifier, and a highly reliable cooler that is very compact. Fundamental design of the CRFE is investigated. First, the equivalent noise temperature of the CRFE and the effect of improving CRFE sensitivity on base station reception are discussed. Next, essential technologies and fundamental characteristics of each component are described. Finally, influence of antenna noise, such as ground noise and man-made noise, is estimated through field tests both in urban and suburban areas.

  • An Experimental SAR Estimation of Human Head Exposure to UHF Near Fields Using Dry-Phantom Models and a Thermograph

    Toshio NOJIMA  Sadayuki NISHIKI  Takehiko KOBAYASHI  

     
    INVITED PAPER

      Vol:
    E77-B No:6
      Page(s):
    708-713

    An experimental SAR (Specific Absorption Rate) estimation system based upon the thermograph method using a thermograph camera and newly developed homogeneous dry-phantom human models are presented. Experiments are conducted using this system and UHF fields to obtain SAR distributions in the human head irradiated by hand-held portable radios. Experiment results show that the estimated peak SAR's due to the radiation waves from radios of 1W transmitting power are lower than 2W/kg and so conform to the recommendations of the radio-frequency radiation safety guidelines. The developed system enables the surface SAR distributions on the phantom model to be precisely estimated; a function not available with the original system. System parameters required for providing precise estimations are discussed first, and then experiments are conducted to estimate SAR's in the human head exposed to a UHF hand-held portable radio's near field. Finally, estimated data are examined from the viewpoint of radio-frequency exposure safety guidelines.

  • FOREWORD

    Yoshio KOBAYASHI  Toshio NOJIMA  

     
    FOREWORD

      Vol:
    E79-C No:5
      Page(s):
    599-599
  • FOREWORD

    Yoji NAGASAWA  Kunio SAWAYA  Yoshio KAMI  Kohji KOSHIJI  Youji KOTSUKA  Takashi SHINOZUKA  Masao TAKI  Toshio NOJIMA  

     
    FOREWORD

      Vol:
    E80-B No:5
      Page(s):
    643-644
  • Plane-Wave and Vector-Rotation Approximation Technique for Reducing Computational Complexity to Simulate MIMO Propagation Channel Using Ray-Tracing Open Access

    Wataru YAMADA  Naoki KITA  Takatoshi SUGIYAMA  Toshio NOJIMA  

     
    PAPER-Antennas and Propagation

      Vol:
    E92-B No:12
      Page(s):
    3850-3860

    This paper proposes new techniques to simulate a MIMO propagation channel using the ray-tracing method for the purpose of decreasing the computational complexity. These techniques simulate a MIMO propagation channel by substituting the propagation path between a particular combination of transmitter and receiver antennas for all combinations of transmitter and receiver antennas. The estimation accuracy calculated using the proposed techniques is evaluated based on comparison to the results calculated using imaging algorithms. The results show that the proposed techniques simulate a MIMO propagation channel with low computational complexity, and a high level of estimation accuracy is achieved using the proposed Vector-Rotation Approximation technique compared to that for the imaging algorithm.

  • Experimental Investigation on RF Characteristics of Cryogenically-Cooled 3W-Class Receiver Amplifier Employing GaN HEMT with Blue Light LED for Mobile Base Stations

    Yasunori SUZUKI  Shoichi NARAHASHI  Toshio NOJIMA  

     
    PAPER

      Vol:
    E97-C No:10
      Page(s):
    930-937

    This paper presents an experimental investigation on the RF characteristics of a 3W-class cryogenically-cooled receiver amplifier employing a gallium-nitride high electron mobility transistor (GaN HEMT) with a blue light for mobile base stations. In general, a cryogenically-cooled receiver amplifier using a GaN HEMT exhibits unstable DC characteristics similar to those found in the current collapse phenomenon because the GaN HEMT loses thermal energy at cryogenic temperatures. The fabricated cryogenically-cooled receiver amplifier achieves stable DC characteristics by injecting blue light into the GaN HEMT instead of thermal energy. Experimental results show that the amplifier achieves fine stable DC characteristics for deviation in the drain-source current from 42% to 5% and RF characteristics for a maximum power added efficiency from 58% to 68% without and with the blue light at 60,K. The fabricated amplifier is effective in reducing the power consumption at cryogenic temperatures. To the best of our knowledge, this paper is the first report regarding RF characteristics of a cryogenically-cooled receiver amplifier using a blue light for mobile base stations.

  • FEM Simulations of Implantable Cardiac Pacemaker EMI Triggered by HF-Band Wireless Power Transfer System

    Naoki TANAKA  Takashi HIKAGE  Toshio NOJIMA  

     
    BRIEF PAPER

      Vol:
    E99-C No:7
      Page(s):
    809-812

    This paper describes a numerical assessment methodology of pacemaker EMI triggered by HF-band wireless power transfer system. By using three dimensional full-wave numerical simulation based on finite element method, interference voltage induced at the connector of the pacemaker inside the phantom that is used for in-vitro EMI assessment is obtained. Simulated example includes different exposure scenarios in order to estimate the maximum interference voltage.

  • Basic Construction of Whole-Body Averaged SAR Estimation System Using Cylindrical-External Field Scanning for UHF Plane Wave Irradiation of Human Models

    Yoshifumi KAWAMURA  Takashi HIKAGE  Toshio NOJIMA  

     
    PAPER-Electromagnetic Analysis

      Vol:
    E93-B No:10
      Page(s):
    2636-2643

    The purpose of this study is to establish a whole-body averaged specific absorption rate (WB-SAR) estimation method using the power absorbed by humans; a cylindrical-external field scanning technique is used to measure the radiated RF (radio-frequency) power. This technique is adopted with the goal of simplifying the estimation of the exposure dosimetry of humans who have different postures and/or sizes. In this paper, to validate the proposed measurement method, we subject numerical human phantom models and cylindrical scanning conditions to FDTD analysis. We design a radiation system that uses a dielectric lens to achieve plane-wave irradiation of tested human phantoms in order to develop an experimental WB-SAR measurement system for UHF far-field exposure condition. In addition, we use a constructed SAR measurement system to confirm absorbed power estimations of simple geometrical phantoms and so estimate measurement error of the measurement system. Finally, we discuss the measurement results of WB-SARs for male adult and child human phantom models.

21-31hit(31hit)

FlyerIEICE has prepared a flyer regarding multilingual services. Please use the one in your native language.